The 3 wires will run under the drainage gravel around the edge of the conservatory and will run up the wall just to the right of the wall basket.
They will pass through the wall and come together in a single pattress box mounted in the conservatory wall.
The box will be sank into the wall just behind Milo to the left of the double plug socket. There is no existing house wiring to the left of the sockets, the mains wiring travels clockwise around the conservatory. I measured up and picked a drilling point on the outside wall which would bring me out central between the plug socket and the corner in the wall.
Drilled through with my super long 8mm masonry bit, slowing down and reducing pressure approaching breakthrough to prevent blasting a hole in the plasterboard.
I threaded a short piece of the 5 awg silicon wire through the hole just to check hole size was OK.
Here's the components for the earthing point, a 26mm deep single pattress box and a 100mm square 3mm thick copper plate. There will be some kind of terminal central in the copper plate, not decided on it's final design yet.
I masked up the plate and marked up the positions for screw holes to mount the plate to the back box. The 3.5mm holes were drilled and countersunk.
You can simply put the pattress box over the hole for the wire, draw round it and the remove the plaster. I used my Dremel with a spiral cutter, it made short work of the plaster, took about 60 seconds to work around the outline of the pattress. The cut out plaster can then be remove with an old flat bladed screwdriver or chisel.
I attached the copper plate to the pattress box and placed it into the cut-out. I am not going to permanently fit the back box yet. I will do it when I address the wiring to the 3 grounding rods.
If you like this blog you can show your support by one or all of these. 1. +1 my blog and email it to a friend. 2. Follow me.... It's good to know someones interested. 3. Leave a comment.... All are appreciated.